| INPUT SPECIFICATIONS |
|
|
˙Input voltage: |
115 Vac: 90-135V 230 Vac: 180 to 265 VAC |
| ˙Input frequency: |
47 to 63 Hz |
| ˙Inrush current: |
80Amps-peak/115Vac 120Amps-peak/230Vac |
| ˙Input current: |
10Amps/115Vac 5Amps/230Vac |
| OUTPUT SPECIFICATIONS |
|
| ˙Over voltage protection: |
+5V output:5.6-6.5V; +3.3V output: 3.8V-4.5V; +12V output: 13.0-14.5V |
| ˙Overload protection: |
+5V:45A ;+3.3V: 45A; +12V CPU: 20A; +12V I/O: 20A |
| ˙Short circuit protection: |
The short circuit on any DC output shall not cause any damage to the power supply, including the primary fuse. |
| GENERAL SPECIFICATIONS |
|
| ˙Hold-up time: |
18ms at 115Vac/60Hz, 18ms at 230Vac/50Hz. |
| ˙Efficiency: |
63% min. 115Vac at full load |
| ˙MTBF: |
100,000 hours at full load at 25℃ |
| ˙Power good signal: |
Turn on delay time 100ms to 500 ms |
ENVIRONMENTAL SPECIFICATIONS
| ˙Operating temperature: |
0℃ to +30℃ |
| ˙Storage temperature: |
-20℃ to +80℃ |
| ˙Relative humidity: |
5% to 95% RH non-condensing | |